FAQ
Pump station questions people actually ask
Short answers on servicing intervals, high-level alarms, emergency repair, packaged station costs and unadopted stations. If your question is not here, use the contact form or telephone 01483 355 003.
How often should a pump station be serviced?
It depends on how hard the station works. As a guide, a low-use domestic station is often well served by an annual visit. Shared stations on blocks, housing developments and commercial sites usually need two visits a year, and high-duty or heavily loaded stations may need four. Stations on the Thames, Wey or Mole floodplains, or those serving kitchens with a heavy load of fats, may also need more frequent tanker emptying. We will say if a proposed schedule looks too light for the site.
What does a pump station service include?
A major service is a 21-point mechanical and electrical check. The pumps are lifted and cleaned, and we inspect the volute, impeller, wear rings, bearings, oil (for water ingress), motor windings and cables, floats or ultrasonic head, lifting gear, isolation and non-return valves, pipework, chamber and covers, and the control panel, including alarms and earth loop resistance. The chamber is cleaned of items that could cause a blockage. A general service is a shorter version of the same inspection. The full list is on the pump station servicing page.
What should I do if the pump station alarm is going off?
Treat it as urgent. Reduce water use if you can, and do not open or enter the chamber or change control-panel settings unless you have been shown how to do so safely. If it is safe, note whether any pump-running lights are on and whether a breaker has tripped, then telephone 01483 355 003 for emergency pump station repair. Do not wait to see if the level drops on its own, particularly on a basement, a car park or a housing development.
Do you offer 24/7 emergency pump station repair?
Yes. Engineers and tankers are available 24 hours a day, 365 days a year, for domestic and commercial sites across Surrey. A typical visit starts with making the site safe, pumping out the chamber if needed, and getting at least one pump running. Telephone support is available throughout the year, with a 24-hour engineer response.
How much does a packaged pumping station cost?
There is no honest single price, because the duty, chamber size, single or twin pumps, rising-main length, excavation and electrical work all change the figure. Small domestic packaged units cost less than a large twin-pump development station with a long rising main and a UK-built control panel. We quote from the site details — or from a visit if drawings are not available — rather than publishing a standard installed cost.
What is a foul water or sewage pumping station, and how does it work?
A foul water, or sewage, pumping station takes wastewater that cannot reach the sewer by gravity and lifts it through a rising main. Waste flows into a chamber, or wet well. When the level reaches a set point, float switches or a level sensor start a submersible pump. A second pump is often fitted as standby or assist. A high-level alarm warns you if the pumps have not kept up. Surface water pumping stations work in the same way, but handle rainwater and runoff rather than sewage.
When does a house or site need a pump station?
A pumping station is needed where foul or surface water cannot drain to the receiving sewer, watercourse or soakaway by gravity. That is common on lower-ground accommodation, in basements, on sloping or low-lying plots, on the floodplains of the Thames, Wey and Mole, and on housing developments laid out below the existing sewer. A sewage lifting station is used inside or next to a building that sits below the backflow level.
Do you offer maintenance contracts?
Yes. We offer planned contracts of 12, 24 or 36 months, with two or four visits a year, and a written report after each service. Tanker desilting and jetting can be built into the agreement. Contract customers can view scheduled visits and reports online. A contract does not replace the need for emergency attendance if a station fails between visits, but it does give you a clear route to that help.
Can you service a station you did not install?
Yes. We maintain and repair stations of any make, design, age or condition, including packaged GRP chambers and older brick or concrete wet wells. If you have inherited a station and have little paperwork, a first inspection and a tanker clean is often the most useful place to start.
What causes a pump station to block or fail?
The usual causes are rag and wipes wrapped around the impeller, fats and grease fouling floats, silt in the sump, a stuck non-return valve letting water run back into the chamber, a tripped breaker, or a pump that is simply worn out. On many Surrey sites, fine clay and grit add to the wear, and storm flows on the Thames, Wey and Mole corridors quickly show up a chamber that has not been desilted or a pump that has not been tested.
Does regular servicing mean the pump will not fail?
No. Servicing reduces avoidable risk and can identify developing problems, but no inspection can eliminate every future failure. That is why a tested high-level alarm, and a way of reaching an engineer at night, still matter on a station that is already on a maintenance contract.
What is Section 104, and who is responsible for an unadopted station?
Section 104 of the Water Industry Act 1991 is the usual route by which a developer agrees that sewers and, where relevant, a pumping station will be adopted by the sewerage undertaker — in most of Surrey, Thames Water. Stations intended for adoption should be designed to the water industry’s Design and Construction Guidance (DCG), which replaced Sewers for Adoption in England. Until adoption is completed, and in every case where a station remains private, responsibility sits with the developer or with the management company or residents who have taken the site on. A service contract does not replace the adoption agreement, but it does keep the station working in the meantime.
Why does a pump station need desilting and jetting?
In normal operation, grease floats and forms a mat at the top of the chamber, and solids settle at the bottom. Left alone, that load fouls floats, starves the pumps and is one of the most common reasons a station goes into alarm. Tanker emptying and high-pressure jetting take the silt, rag and fat out of the wet well. The work is typically built into a service contract once a year, and more often on a busy site. See the desilting and jetting page.
What do you need in order to quote for a new packaged station?
The site location, whether the duty is foul or surface water, a sense of the incoming flow or the number of properties served, the approximate invert level and the discharge point, and any preference for adoption (Section 104) or a private station. If you have drawings or a specification, send them. If you do not, we can help work out the duty from a site visit.
Are your engineers trained for confined-space work?
Yes. Service engineers are trained for confined-space working and take regular refreshers in gas detection, breathing apparatus, confined-space entry procedures and the associated health and safety requirements. That is a basic requirement for working in wet wells, not an optional extra.
Can you provide references?
Yes. References are available on request from schools, churches, factories, large private homes and other sites we look after. We do not publish client names here; if you would like to speak to someone we have worked for, please ask and we will arrange it.